ARE4R 0,6/1kV 1x70
Nexans ref. 10506120
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.8 mm
- Average insulation thickness: 1.1 mm
- Diameter over insulation: 12.2 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 15.6 mm
- Approximate weight: 310 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.568 Ohm/km
- Permissible short circuit current conductor 1s: 6.6 kA
ARE4R 0,6/1kV 1x95
Nexans ref. 10506121
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.5 mm
- Average insulation thickness: 1.1 mm
- Diameter over insulation: 13.9 mm
- Nominal outer sheath thickness: 1.5 mm
- Nominal outer diameter: 17.5 mm
- Approximate weight: 400 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.411 Ohm/km
- Permissible short circuit current conductor 1s: 9 kA
ARE4R 0,6/1kV 1x120
Nexans ref. 10506122
- Conductor cross-section: 120 mm²
- Conductor diameter: 13.1 mm
- Average insulation thickness: 1.2 mm
- Diameter over insulation: 15.7 mm
- Nominal outer sheath thickness: 1.5 mm
- Nominal outer diameter: 19.4 mm
- Approximate weight: 490 kg/km
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.325 Ohm/km
- Permissible short circuit current conductor 1s: 11.3 kA
ARE4R 0,6/1kV 1x150
Nexans ref. 10506123
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.3 mm
- Average insulation thickness: 1.4 mm
- Diameter over insulation: 17.4 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 21.4 mm
- Approximate weight: 600 kg/km
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.265 Ohm/km
- Permissible short circuit current conductor 1s: 14.2 kA
ARE4R 0,6/1kV 1x185
Nexans ref. 10506124
- Conductor cross-section: 185 mm²
- Conductor diameter: 16.0 mm
- Average insulation thickness: 1.6 mm
- Diameter over insulation: 19.5 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 23.6 mm
- Approximate weight: 730 kg/km
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.211 Ohm/km
- Permissible short circuit current conductor 1s: 17.5 kA
ARE4R 0,6/1kV 1x240
Nexans ref. 10506125
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.5 mm
- Average insulation thickness: 1.7 mm
- Diameter over insulation: 22.2 mm
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 26.7 mm
- Approximate weight: 940 kg/km
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.162 Ohm/km
- Permissible short circuit current conductor 1s: 22.7 kA
ARE4R 0,6/1kV 1x300
Nexans ref. 10506126
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.7 mm
- Average insulation thickness: 1.8 mm
- Diameter over insulation: 24.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 29.3 mm
- Approximate weight: 1130 kg/km
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.13 Ohm/km
- Permissible short circuit current conductor 1s: 28.3 kA
ARE4R 0,6/1kV 1x400
Nexans ref. 10506127
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.5 mm
- Average insulation thickness: 2.0 mm
- Diameter over insulation: 27.8 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 32.9 mm
- Approximate weight: 1420 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0778 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.102 Ohm/km
- Permissible short circuit current conductor 1s: 37.8 kA
Description
Description
Standards
-
ProductIEC 60502-1
Description
Single core cables with aluminium conductor, XLPE insulation, PVC outer sheath.
Application:
Suitable for fixed installation indoor or outdoor laying in air or indirectly buried.
Construction
- Conductor: stranded, compacted, round aluminum – Cl. 2 (CEI EN 60228).
- Insulation: extruded polyethylene (XLPE) compound. Colour: black.
- Outer sheath: extruded PVC compound. Colour: grey.
Functional characteristics
- Rated voltages U0/U: 0,6/1 kV
- Max. operating temperature of conductor: 90°C
- Max. short circuit temperature of conductor: 250°C (max 5s)
- Min. installation temperature: 0°C
- Max. tensile strength on the conductor during installation: 50 N/mm2
- Min. bending radius during installation: 6 Dcable
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Aluminum
Conductor shape
Round, stranded and compacted
Conductor flexibility
Class 2 IEC 60228
Insulation
Extruded XLPE compound
Insulation colour
Black
Lay Up
Single core
Outer sheath
PVC compound
Sheath colour
Grey
Dimensional characteristics
Dimensional characteristics
Number of cores
1
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV