- Markets
- Products
- Newsroom
- About Nexans
- Tools & Resources
- Search
- Contact us
- Compare
- Sign in
Study 122106
Nexans ref.
- Maximum outer diameter: 3.0 mm
- Approximate weight: 12 g/m
- Operating voltage: 250 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 80 °C
- Minimum operating temperature: -20 °C
Study 132196
Nexans ref.
- Maximum outer diameter: 2.9 mm
- Approximate weight: 13.6 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 132798
Nexans ref. Etude 132798
- Maximum outer diameter: 4.1 mm
- Approximate weight: 22.7 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 132836
Nexans ref.
- Maximum outer diameter: 1.05 mm
- Approximate weight: 2.11 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 150 °C
- Minimum operating temperature: -30 °C
Study 132857
Nexans ref.
- Maximum outer diameter: 4.1 mm
- Approximate weight: 19.12 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 132923
Nexans ref.
- Maximum outer diameter: 4.1 mm
- Approximate weight: 22.35 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 90 °C
- Minimum operating temperature: -40 °C
Study 133144
Nexans ref. Etude 133144
- Maximum outer diameter: 6.15 mm
- Approximate weight: 51.54 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 133148
Nexans ref. Etude 133148
- Maximum outer diameter: 4.15 mm
- Approximate weight: 21.57 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 133198
Nexans ref. Etude 133198
- Maximum outer diameter: 7.4 mm
- Approximate weight: 77 g/m
- Operating voltage: 250 V
- Cable flexibility: Flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 133213
Nexans ref. Etude 133213
- Maximum outer diameter: 1.7 mm
- Approximate weight: 5 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 200 °C
- Minimum operating temperature: -30 °C
Study 133239
Nexans ref. Etude 133239
- Maximum outer diameter: 5.1 mm
- Approximate weight: - g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -20 °C
Study 133255
Nexans ref. Etude 133255
- Maximum outer diameter: 0.93 mm
- Approximate weight: 1.27 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 200 °C
- Minimum operating temperature: -55 °C
Study 133261
Nexans ref. Etude 133261
- Maximum outer diameter: 2.1 mm
- Approximate weight: 7.55 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 133274
Nexans ref.
- Maximum outer diameter: 1.5 mm
- Approximate weight: - g/m
- Operating voltage: 35 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: 20 °C
Study 133471
Nexans ref. Etude 133471
- Maximum outer diameter: 2.3 mm
- Approximate weight: 8.25 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 150 °C
- Minimum operating temperature: -30 °C
Study 133475
Nexans ref. Etude 133475
- Maximum outer diameter: 2.5 mm
- Approximate weight: 10 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 150 °C
- Minimum operating temperature: -30 °C
Study 133478
Nexans ref.
- Maximum outer diameter: 3.4 mm
- Approximate weight: 19 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 133483
Nexans ref.
- Maximum outer diameter: 3.0 mm
- Approximate weight: 16 g/m
- Operating voltage: 12 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 200 °C
- Minimum operating temperature: -30 °C
Study 133491
Nexans ref. Etude 133491
- Maximum outer diameter: 4.15 mm
- Approximate weight: 26 g/m
- Operating voltage: 30 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 80 °C
- Minimum operating temperature: -40 °C
Study 133499
Nexans ref. Etude 133499
- Maximum outer diameter: 2.05 mm
- Approximate weight: 8.34 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 200 °C
- Minimum operating temperature: -50 °C
Study 133515
Nexans ref. Etude 133515
- Maximum outer diameter: 4.32 mm
- Approximate weight: 29 g/m
- Operating voltage: 5 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 133529
Nexans ref. Etude 133529
- Maximum outer diameter: 3.6 mm
- Approximate weight: 20 g/m
- Operating voltage: 24 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 85 °C
- Minimum operating temperature: -30 °C
Study 133606
Nexans ref.
- Maximum outer diameter: 4.2 mm
- Approximate weight: 17 g/m
- Operating voltage: 250 V
- Cable flexibility: Very flexible
- Maximum operating temperature: 60 °C
- Minimum operating temperature: -20 °C
Description
Description
Standards
-
ProductNexans specification
Design
- Biocompatible materials
- Miniaturized construction down to AWG52
- Customized design
- Cosmetic adaptibility
- Very flexible
- High electromagnetic immunity
Sterilization
The product range can resist many kinds of sterilization :
- Chemical (ETO, Sterad, Cidex, etc.)
- Gazeous (Formaldehyde, etc.)
- Gamma rays
- Autoclave
and can be cleaned with alcohol (ethanol, propanol, etc.)
Production
Modelisation tools for design optimization.
Reliable quality process.
ISO 13485 certification.
Various test equipments for in line and off line control.
For more information, please contact-us
Characteristics
Characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania