ARE4*OCR 0,6/1kV 3x95+35C CU

Description

Description

Standards

  • National
    DC 4126

Multicore cables with concentric conductor. Phases with aluminium conductor and XLPE insulation, copper concentric conductor, PVC outer sheath.

Cables compliant with the requirements of the Construction Products Regulation “CPR (EU) n° 305/2011”.

Fire performance class:  Fca

Application:

Suitable for fixed installation laying indirectly buried.

Construction:

  • Conductor: solid, round aluminium – Cl. 1 (CEI EN 60228) (up to 10 mm2);
  • stranded, compacted, round aluminium – Cl. 2 (CEI EN 60228) (above 10 mm2).
  • Insulation: extruded polyethylene (XLPE) compound.
  • Filler: extruded not hygroscopic compound.
  • Concentric conductor: copper wires (CU).
  • Binder tape: copper tape.
  • Outer sheath: extruded PVC compound. Colour: grey.

Core identification according to DC 4126:

Three cores:

  • brown - black - blue

Functional characteristics:

  • Rated voltages U0/U: 0,6/1 kV
  • Max. operating temperature of conductor (phase): 90°C
  • Max. short circuit temperature of conductor (phase): 250°C (max 5s)
  • Min. installation temperature: 0°C
  • Max. tensile strength on the conductor during installation: 50 N/mm2
  • Min. bending radius during installation: 8 Dcable 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Round, stranded and compacted
Conductor flexibility
Class 2 acc. to IEC 60228
Insulation
Extruded XLPE compound
Insulation colour
Brown / Black / Blue
Lay Up
Multicores
Material of filler / inner sheath
Not hygroscopic extruded compound
Concentric conductor
Copper wires (waveform) and copper binder tape
Concentric conductor cross section
35 mm²
Outer sheath
PVC compound
Sheath colour
Grey

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
95 mm²
Conductor diameter
11.5 mm
Average insulation thickness
1.1 mm
Diameter over insulation
13.9 mm
Average sheath thickness
2.2 mm
Nominal outer diameter
40.2 mm
Approximate weight
2340 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000783-ITBP
  • Certification Date : 12/10/20
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0051
  • Declared performance : Fca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close