ARE4*OCE 0,6/1kV 3x25+16C IT

Description

Description

Standards

  • Product
    GSCC014

Multicore cables with concentric conductor. Phases with aluminium conductor and XLPE insulation, copper concentric conductor, polyolefin outer sheath.

Cables compliant with the requirements of the Construction Products Regulation “CPR (EU) n° 305/2011”.

Fire performance class:  Eca

Application:

Suitable for fixed installation laying indirectly buried.

Construction:

  • Conductor: solid, round aluminium – Cl. 1 (CEI EN 60228) (up to 10 mm2);
  • stranded, compacted, round aluminium – Cl. 2 (CEI EN 60228) (above 10 mm2).
  • Insulation: extruded polyethylene (XLPE) compound.
  • Filler: extruded not hygroscopic compound.
  • Concentric conductor: copper wires (CU).
  • Binder tape: copper tape.
  • Outer sheath: extruded polyolefin (PO) compound. Colour: grey.

Core identification according to GSCC014:

Three cores:

  • brown - black - blue

Functional characteristics:

  • Rated voltages U0/U: 0,6/1 kV
  • Max. operating temperature of conductor (phase): 90°C
  • Max. short circuit temperature of conductor (phase): 250°C (max 5s)
  • Min. installation temperature: -25°C
  • Max. tensile strength on the conductor during installation: 50 N/mm2
  • Min. bending radius during installation: 8 Dcable 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Round, stranded and compacted
Conductor flexibility
Class 2 acc. to IEC 60228
Insulation
Extruded XLPE compound
Insulation colour
Brown / Black / Blue
Lay Up
Multicores
Material of filler / inner sheath
Not hygroscopic extruded compound
Concentric conductor
Copper wires (unidirectional or waveform) and copper binder tape
Concentric conductor cross section
16 mm²
Outer sheath
Extruded polyolefin-based thermoplastic compound
Sheath colour
Grey

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
25 mm²
Conductor diameter
6.0 mm
Average insulation thickness
0.9 mm
Diameter over insulation
8.0 mm
Average sheath thickness
2.0 mm
Nominal outer diameter
26.4 mm
Approximate weight
860 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1001213-ITBP
  • Certification Date : 3/11/24
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0051
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close